Study of Community Well Water in Giwangan Subdistrict, Yogyakarta City in Terms of Quantity (Depth) and Quality (pH, Temperature, Fe, DO, Total Coliform Parameters)
Keywords:
Water Quality, Land Use Planning, GISAbstract
The prolonged drought in Yogyakarta City in 2023 caused residents in Giwangan Village to deepen their wells due to concerns about groundwater depletion. The quality of septic tanks in Giwangan is also poor, with only 26.7% categorized as safe and 73.3% considered unsafe, indicating the need for better water management in this densely populated area. This study aims to measure the pH level, temperature, iron (Fe), dissolved oxygen (DO), and total coliform due to high human activity at the end of the 2023 peak dry season, as well as to determine the depth of the groundwater table visualized through a geographic information system (GIS). The research method used is descriptive quantitative analysis, with the analysis of field survey results and laboratory tests. Samples were taken from 4 wells in densely populated residential areas and 2 wells near the Gajah Wong River. This study refers to the Indonesian Ministry of Health Regulation Number 32 of 2017 concerning environmental health quality standards. The research results showed that the shallowest groundwater table was 3.9 meters in well S-3, while the deepest was 8.9 meters in well S-2. Visualization of the water flow direction showed flow towards wells S2 and S3. In terms of water quality, the parameters of pH, temperature, iron (Fe), and dissolved oxygen (DO) met the criteria for clean water, but only one well met the total coliform standard